NONSHRINK HYDRAULIC CEMENT GROUTS
GENERAL
Acceptance of nonshrink hydraulic cement grouts will be on the basis of approved brands and satisfactory certifications. These materials are approved for use when the plans or specifications permit their use for grouting purposes. Brand names must be identifiable on the containers. Approved manufacturers and brands of nonshrink hydraulic cement grouts are listed in the Materials Approved Products Listing Enterprise (MAPLE).
When a grout is to be used in contact with stressed tendons or other corrosion-sensitive, load-bearing structural members, the user shall make sure the material meets relevant chloride, nitrite, sulfide and sulfate requirements, and any other material limitations imposed by the applicable Iowa DOT specifications. As noted, some grouts listed on Appendix A have the acid-soluble chloride content lower than 0.08% by weight per ASTM C 1152 or AASHTO T 260.
ACCEPTANCE
Prior to being placed on the list of approved brands, a product will be tested and evaluated by the Office of Construction and Materials based on the following criteria:
A. Compressive Strength |
ASTM C 109 |
|
|
|
|
Fluid or Flowable State |
1 day |
1000 psi, minimum |
|
7 days |
3500 psi, minimum |
|
|
|
B. Height Change (Plastic or Flowable State) |
||
|
|
|
Early Age |
ASTM C 827 |
|
|
(The manufacturer shall provide independent test result of C 827 for evaluation) |
At final set, the grout must not shrink, and the grout must not expand by more than +4.0%. |
|
|
|
Hardened Grout |
ASTM C 1090 |
+0.3% maximum and 0.0% minimum at 1, 3, 14 and 28 days |
When casting specimens for above tests, consistency shall meet the following requirements:
Fluid State |
ASTM C 939/IM 375 |
10 - 30 seconds |
Flowable State |
ASTM C 1437 |
125 - 145 |
Plastic State |
ASTM C 1437 |
100 - 125 |
If the manufacturer can provide independent test results, some of the above tests may be waived.
CERTIFICATION
The manufacturer shall file a certification with the Office of Construction and Materials at the beginning of each calendar year stating that the material supplied during that year is identical with the formulation previously tested and approved.
MONITOR SAMPLING & TESTING
The Office of Construction and Materials may sample and test hydraulic cement grouts to verify their capability of meeting the approval requirements