Sampling & Testing Guide-Minimum Frequency |
||||||||
October 18, 2016 |
ACCEPTANCE OF SMALL QUANTITIES OF MATERIALS |
Matls. IM 204 |
||||||
Supersedes October 21, 2014 |
|
Appendix X |
||||||
Material |
Maximum Quantity |
Specifications |
Alternate Acceptance Method |
|||||
Aggregate, non-proportioned, non-critical |
200 tons |
Approved Source and Visual |
||||||
Asphalt, HMA |
Mix |
mixture bid item of 1000 tons |
Approved JMF, Contractor QC, and Contractor Certification |
|||||
Binder |
mixture bid item of 1000 tons |
Approved Source and Supplier Certification |
||||||
Aggregate |
mixture bid item of 1000 tons |
Approved Source, Producer Certification for gradation and quality, and Contractor QC. |
||||||
Concrete, PCC Paving |
Aggregate |
Less than 2000 Square Yards of Concrete |
Approved Source, Producer Certification for gradation and quality, Agency gradation verification, and Contractor QC. |
|||||
Less than 10 Cubic Yards of Concrete or Non- structural items Defined in IM 528 |
Approved Source, Producer Certification for gradation and quality, and Contractor QC. |
|||||||
Portland Cement |
Less than 2000 Square Yards of Concrete |
Approved Source and Producer Certification |
||||||
Fly Ash |
Less than 2000 Square Yards of Concrete |
Approved Source and Producer Certification |
||||||
GGBFS |
Less than 2000 Square Yards of Concrete |
Approved Source and Producer Certification |
||||||
Admixtures |
Less than 2000 Square Yards of Concrete Yards |
Approved Source |
||||||
White Pigmented Cure |
55 gallons or less |
Visual |
||||||
Sampling & Testing Guide-Minimum Frequency |
||||||||
October 18, 2016 |
ACCEPTANCE OF SMALL QUANTITIES OF MATERIALS |
Matls. IM 204 |
||||||
Supersedes October 21, 2014 |
|
Appendix X |
||||||
Concrete, PCC Structural |
Aggregate |
Less than 50 Cubic Yards of Concrete |
Approved Source, Producer Certification for gradation and quality, Agency gradation verification, and Contractor QC. |
|||||
Less than 10 Cubic Yards of Concrete or Non- structural items Defined in IM 528 |
Approved Source, Producer Certification for gradation and quality, and Contractor QC. |
|||||||
Portland Cement |
Less than 50 Cubic Yards of Concrete |
Approved Source and Producer Certification |
||||||
Admixtures |
Less than 50 Cubic Yards of Concrete |
Approved Source |
||||||
White Pigmented Cure |
55 gallons or less |
Visual |
||||||
Dowel Baskets, Epoxy-coated |
25 |
|
Visual & Field Check |
|||||
Hardware for Timber |
100 lbs. |
Visual |
||||||
Joint Filler, Preformed |
50 ft. |
Visual & Dimension |
||||||
Lighting Material-Conduit & Fittings |
100 ft |
Visual & Brand Name |
||||||
Paint, Bridge |
5 gal. |
Visual & Brand Name |
||||||
Pipe, Welded Steel for Bridge Railing |
100 ft. |
Letter of Compliance |
||||||
Signing, Delineator posts |
10 |
Visual |
||||||
Steel Reinforcement, Epoxy Coated (other than bridge decks) |
Less than 5 tons |
Approved Source, Producer Certification |
||||||
Steel Reinforcement, Uncoated |
Less than 45 tons |
Approved Source, Producer Certification |
||||||
Steel Reinforcement, Stainless |
Less than 1 ton |
Approved Source, Producer Certification |
||||||