ROADWAY & BORROW EXCAVATION & EMBANKMENTS
MATERIAL OR CONSTRUCTION ITEM |
TESTS
|
METHOD OF ACCEPTANCE & RELATED
IMs
|
QUALITY
CONTROL
|
INDEPENDENT
ASSURANCE
&
VERIFICATION S&T
|
REMARKS
|
|||||||||
SAMPLE BY |
FREQ. |
SAMPLE SIZE |
TEST BY |
REPORT |
S&T TYPE |
SAMPLE BY |
FREQ. |
SAMPLE SIZE |
TEST BY |
REPORT |
|
|||
SOURCE INSPECTION
|
||||||||||||||
Special Backfill Crushed Stone (4132.02) Crushed Concrete (4132.02) RAP (2303.02) Gravel (4132.03) |
|
AS 209
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
AS 209 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Granular Backfill |
Quality |
AS 209
|
|
|
|
|
|
|
|
|
|
|
|
|
Engr. Fabric (4196) |
Quality |
AS 496.01 |
|
|
|
|
|
|
|
|
|
|
|
|
GRADE INSPECTION
|
||||||||||||||
Moisture Control, (QC by Contractor) Note 1 |
Proctor
|
CONTR |
1/ soil class |
25 lb |
CONTR |
Field Book & Test Report |
V
IA (4) |
CONTR/RCE CONTR/DME |
1/ 10 req’d QC tests (min. 1)(5) 1/proj. |
25 lb.
25 lb. |
RCE/ DME CTRL |
Field Book
Test Report |
|
|
Moisture
|
CONTR |
1/lift/1500 ft (for max of 1300 cy) |
3 lb |
CONTR |
Field Book & Test Report |
V
IA (4) |
CONTR/RCE DME |
1/ 10 req’d QC tests (min. 1)(5) Witness 1/proj. |
1.1 lb. |
RCE |
Field Book |
Note 2 |
||
Moisture & Density Control, including Special Compaction of Subgrade (2109.03C), (QC by Contractor) Note 1 |
Proctor
|
CONTR |
1/ soil class |
25 lb |
CONTR |
Field Book & Test Report |
V
IA (4) |
CONTR/RCE CONTR/DME |
1/ 10 req’d QC tests (min. 1)(5) 1/proj. |
25 lb.
25 lb. |
RCE/ DME CTRL |
Field Book
Test Report |
|
|
Moisture
|
CONTR |
1/lift/1500 ft.(for max of 1300 cy) |
3 lb |
CONTR |
Field Book & Test Report |
V
IA (4) |
CONTR/RCE DME |
1/ 10 req’d QC tests (min. 1)(5) Witness 1/proj. |
1.1 lb. |
RCE |
Field Book |
Note 2 |
||
In-place Density |
CONTR |
1/lift/1500 ft (for max of 1300 cy) |
As req’d by test |
CONTR |
Field Book & Test Report |
V
IA (4) |
RCE/ DME DME |
1/10 req’d QC tests (min. 1)(5) Witness 1/proj. |
|
RCE/ DME |
Field Book |
Note 3 |
||
Note 1: When Contractor QC testing is not required in the contact documents. The RCE will perform verification testing at the frequency listed for QC. |
||||||||||||||
Note 2: RCE will direct the Contractor to take a moisture sample beside the RCE verification sample location. |
||||||||||||||
Note 3: If testing is done with a portable moisture-density gauge, the gauge calibration will be verified on the ValiDator block. |
||||||||||||||
Note 4: For earthwork quantities of less than 50,000 Yd3, No IA will be required. |
||||||||||||||
Note 5: If no QC tests are required, then no verification or independent assurance tests are required. |