Minimum Energy Required for Diesel Hammers (Ft. - Kips(b)) |
|||||||||
Pile Length
|
Wood Pile
|
Concrete Pile |
Steel H-Pile |
||||||
12" to 14" |
16" |
10 x 42 |
10 x 57 |
12 x 53 |
12 x 74 |
14 x 73 |
14 x 89 |
||
25' or less |
17 |
23 |
28 |
22 |
24 |
24 |
29 |
29 |
33 |
Maximum Energy Allowed for Diesel Hammers (Ft. - Kips(b)) |
|||||||||
Pile Length
|
Wood Pile
|
Concrete Pile |
Steel H-Pile |
||||||
12" to 14" |
16" |
10 x 42 |
10 x 57 |
12 x 53 |
12 x 74 |
14 x 73 |
14 x 89 |
||
25' or less 51’ to 65’ |
24 |
32 |
40 |
33 |
33 |
33 |
40 |
40 |
43 |
(a) Wave equation analysis. |
|||||||||
(b) Ft. - Kips - 1000 foot pounds. |
|||||||||
For nominal bearing resistances under 105 tons, minimum diesel hammer energies listed may be reduced by 20% for concrete pile and 10% for steel pile. |
Property |
Test Method |
Units |
Armor Unit |
Articulating Block Mat |
Composition of Yarns |
|
|
Nylon or Polyester |
Nylon or Polyester |
Mass Per Unit Area (double-layer) |
ASTM D 5261 |
oz/yd2 |
14 |
12 |
Thickness |
ASTM D 5199 |
Mils |
28 |
25 |
Mill Width |
|
In |
76 |
76 |
Wide-Width Strip Tensile Strength -Machine |
ASTM D 4595 |
lbf/in |
190 |
140 |
- Cross |
ASTM D 4595 |
lbf/in |
140 |
110 |
Elongation at Break - Machine |
ASTM D 4595 |
% |
20 |
20 |
- Cross |
ASTM D 4595 |
% |
30 |
30 |
Trapezoidal Tear Strength - Machine |
ASTM D 4533 |
lbf |
180 |
150 |
- Cross |
ASTM D 4533 |
lbf |
115 |
100 |
Apparent Opening Size (AOS) |
ASTM D 4751 |
U.S. Std. Sieve |
60 |
40 |
Flow Rate |
ASTM D 4491 |
gal/min/ft2 |
50 |
90 |
Notes: a. Conformance of fabric to specification property requirements is based on ASTM D 4759. b. All numerical values represent minimum average roll values (i.e., average of test results from any sample roll in a lot shall meet or exceed the minimum values). Sample lots according to ASTM D 4354. |
Table 2552.02-1: Class II Material
Class |
Type |
Soil Group Symbol ASTM D 2487 |
Description |
Percentage Passing Sieve Sizes |
||
1½ in. |
No. 4 |
No. 200 |
||||
II |
Coarse-Grained Soils, clean |
GW |
Well-graded gravels and gravel-sand mixtures; little or no fines |
100% |
‹50% of “Coarse Fraction” |
‹5% |
GP |
Poorly-graded gravels and gravel-sand mixtures; little or no fines. |
|||||
SW |
Well-graded sands and gravelly sands; little or no fines. |
›50% of “Coarse Fraction” |
||||
SP |
Poorly-graded sands and gravelly sands; little or no fines. |
|||||
Coarse-Grained Soils, borderline clean to with fines |
e.g. GW-GC, SP-SM |
Sands and gravels which are borderline between clean and with fines. |
100% |
Varies |
5% to 12% |
Table 2552.02-2: Class III Material
Class |
Type |
Soil Group Symbol ASTM D 2487 |
Description |
III |
Coarse-Grained Soils, with fines |
GM |
Silty gravels, gravel-sand-silt mixtures. |
GC |
Clayey gravels, gravel-sand-clay mixtures. |
||
SM |
Silty sands, sand-silt mixtures. |
||
SC |
Clayey sands, sand-clay mixtures. |
Table 2552.02-3: Class IVA Material
Class |
Type |
Soil Group Symbol ASTM D 2487 |
Description |
IVA |
Fine-Grained Soils (inorganic) |
ML |
Inorganic silts and very fine sands, rock flour, silty or clayey fine sands, silts with slight plasticity. |
CL |
Inorganic clays of low to medium plasticity, gravelly clays, sandy clays, silty clay, lean clays. |
Table 2552.02-4: Class IVB Material
Class |
Type |
Soil Group Symbol ASTM D 2487 |
Description |
IVB |
Fine-Grained Soils (inorganic) |
MH |
Inorganic silts, micaceous or diatomaceous fine sandy or silty soils, elastic silts. |
CH |
Inorganic clays of high plasticity, fat clays. |
Class |
Type |
Soil Group Symbol ASTM D 2487 |
Description |
V |
Organic Soils (Unsuitable for backfill) |
OL |
Organic silts and organic silty clays of low plasticity. |
|
OH |
Organic clays of medium to high plasticity, organic silts. |
|
Highly Organic (Unsuitable for backfill) |
PT |
Peat and other high organic soils. |
TABLE 4109.02-1: AGGREGATE GRADATION TABLE |
||||||||||||||
Grad. No. |
Section No. |
Std. Sieve Sz. |
1 1/2” |
1.00” |
3/4” |
1/2” |
3/8” |
4 |
8 |
30 |
50 |
100 |
200 |
|
Intended Use |
Percent Passing |
Notes |
||||||||||||
1 |
4110, 4125, 4133, 4134 |
PCC FA, Cover Agg. |
|
|
|
|
100 |
90-100 |
70-100 |
10-60 |
|
|
0-1.5 |
1 |
2 |
4112 |
PCC Intermediate |
|
|
|
95-100 |
|
|
0-10 |
|
|
|
|
|
3 |
4115 (57, 2-8), 4118 |
PCC CA |
100 |
95-100 |
|
25-60 |
|
0-10 |
0-5 |
|
|
|
0-1.5 |
2, 10 |
4 |
4115 (2-8) |
PCC CA |
100 |
50-100 |
30-100 |
20-75 |
5-55 |
0-10 |
0-5 |
|
|
|
0-1.5 |
10 |
5 |
4115 (67, 2-8) |
PCC CA |
|
100 |
90-100 |
|
20-55 |
0-10 |
0-5 |
|
|
|
0-1.5 |
10 |
6 |
4115.06 (Repair & Overlay) |
PCC CA |
|
|
100 |
90-100 |
40-90 |
0-30 |
|
|
|
|
0-1.5 |
10 |
7 |
4117 (Class V) |
PCC FA & CA |
100 |
|
|
|
|
80-92 |
60-75 |
20-40 |
|
|
|
|
8 |
4117.03 (Class V) |
Fine Limestone |
|
|
|
|
100 |
90-100 |
|
|
|
|
0-30 |
|
9 |
2556 |
Grout Aggregate |
|
|
|
100 |
85-100 |
|
0-10 |
|
|
|
0-1.5 |
|
10 |
4119, 4120.02, 4120.03 (C gravel) |
Granular Surface |
|
|
100 |
|
|
50-80 |
25-60 |
|
|
|
|
3, 11 |
11 |
4119, 4120.02, 4120.04, 4120.05, 4120.07, (A, B Cr. St.) |
Granular Surface & Shoulder |
|
100 |
95-100 |
70-90 |
|
30-55 |
15-40 |
|
|
|
6-16 |
4, 5, 11 |
12a |
4121 (Cr. St.) |
Granular Subbase |
100 |
|
|
40-80 |
|
|
5-25 |
|
|
|
0-6 |
6, 11 |
12b |
4121 (Cr. Gravel) |
Granular Subbase |
100 |
|
|
50-80 |
|
|
10-30 |
|
5-15 |
|
3-7 |
7, 11 |
13a |
4122.02 (Cr. St.) |
Macadam St. Base |
3” nominal maximum size screened over 3/4” or 1.00” screen. |
|
||||||||||
13b |
4122.02 |
Macadam Choke St. |
|
100 |
|
|
|
|
|
|
|
|
6-16 |
11 |
14 |
4123 |
Modified Subbase |
100 |
|
70-90 |
|
|
|
10-40 |
|
|
|
3-10 |
5, 7, 11 |
19 |
4125 (1/2”) Cr. Gr. or Cr. St.) |
Cover Aggregate |
|
|
100 |
97-100 |
40-90 |
0-30 |
0-15 |
|
|
|
0-1.5 |
11 |
20 |
4125 (1/2” Scr. Gr.) |
Cover Aggregate |
|
|
100 |
95-100 |
40-80 |
0-15 |
0-7 |
|
|
|
0-1.5 |
11 |
21 |
4125 (3/8”) |
Cover Aggregate |
|
|
|
100 |
90-100 |
10-55 |
0-20 |
0-7 |
|
|
0-1.5 |
11 |
22 |
4124 |
Fine Slurry Mixture |
|
|
|
|
100 |
85-100 |
40-95 |
20-60 |
14-35 |
10-25 |
5-25 |
9, 11 |
23 |
4124 (Cr. St.) |
Coarse Slurry Mixture |
|
|
|
|
100 |
70-90 |
40-70 |
19-42 |
|
|
5-15 |
11 |
29 |
4131 |
Porous Backfill |
|
|
100 |
95-100 |
50-100 |
0-50 |
0-8 |
|
|
|
|
11 |
30 |
4132.02 (Cr. St.) |
Special Backfill |
100 |
|
|
|
|
|
10-40 |
|
|
|
0-10 |
5, 11, 14 |
31 |
4132.03 (Gravel) |
Special Backfill |
|
100 |
90-100 |
75-100 |
|
|
30-55 |
|
|
|
3-7 |
11 |
32 |
4133 (Sand/Gr./Cr. St.) |
Granular Backfill |
100% passing the 3” screen |
10-100 |
|
|
|
0-10 |
8, 11 |
|||||
35 |
4134 (Natural Sand/Gr.) |
Floodable Backfill |
100 |
|
|
|
|
|
20-90 |
|
|
|
0-4 |
11 |
36 |
4134 (Natural Sand) |
Floodable Backfill |
|
|
|
|
|
100 |
|
|
|
|
0-2 |
11 |
37 |
2320 (Quartzite/Granite/Slag) |
Polymer-Modified Microsurfacing |
|
|
|
|
100 |
90-100 |
65-90 |
30-50 |
18-30 |
10-21 |
5-15 |
12, 13 |
38 |
2320 (limestone/Dolomite) |
Polymer-Modified Microsurfacing |
|
|
|
|
100 |
70-90 |
45-70 |
15-35 |
10-25 |
5-20 |
5-15 |
12, 13 |
Notes: (Gradations No. 9, 15, 16, 17, 18, 24, 25, 26, 27, 28,
33, and 34 have been deleted)
1. For Section 4110, when the fine aggregate is sieved through the following numbered sieves - 4, 8, 16, 30, 50, and 100 - no more than 40% shall pass one sieve and be retained on the sieve with the next higher number.
2. When used in precast and prestressed concrete bridge beams, 100% shall pass the 1.00" sieve. When used for pipe bedding the No. 200 restriction does not apply.
3. When compaction of material is a specification requirement, the minimum percent passing the No. 200 sieve is 6%.
4. See specifications for combination of gravel and limestone.
5. Unwashed air dried samples of crushed composite material shall be tested for gradation compliance except that no gradation determination will be made for material passing the No. 200 sieve.
6. The gradation requirement for the No. 8 sieve shall be 5% to 20% when recycled material is supplied.
7. For Section 4121 gravel, one fractured face on 30% or more of the particles retained on the 3/8 inch sieve. For Section 4123 gravel, one fractured face on 75% or more of the particles retained on the 3/8 inch sieve.
8. Crushed stone shall have 100% passing the 1½” sieve.
9. Gradation limitations for the 30, 50, and 100 sieves shall not apply when slurry mixture is applied by hand lutes, such as for slurry leveling.
10. Maximum of 2.5% passing the No. 200 sieve allowed if for crushed limestone or dolomite when documented production is 1% or less.
11. When Producer gradation test results are used for acceptance, test results representing at least 90% of the material being produced shall be within the gradation limits and the average of all gradation results shall be within the gradations limits. Stockpiled material not meeting the criteria may, at the District Materials Engineer’s discretion, be resampled using Materials I.M. 301 procedures. One hundred percent of the stockpile quality control and verification test results shall be within the gradation limits.
12. For Quartzite/Granite/Slag: 45% to 70% passing No. 16 Sieve; for Dolomite/Limestone: 25% to 50% passing No. 16 Sieve.
13. Percent passing shall not go from the high end to the low end of the range for any two consecutive screens.
14. If the material meets the quality requirements of Article 4120.04, a maximum of 14% passing the No. 200 sieve will be allowed.