Sampling & Testing Guide-Minimum Frequency |
|||||||||||||||||||||
October 15, 2019 |
ROADWAY & BORROW EXCAVATION & EMBANKMENTS |
Matls. IM 204 |
|||||||||||||||||||
Supersedes April 16, 2019 |
Sections 2102, 2107, 2109 & 2432 |
Appendix A (US) Units |
|||||||||||||||||||
MATERIAL OR CONSTRUCTION ITEM |
TESTS |
METHOD OF ACCEPTANCE & RELATED IMs |
QUALITY CONTROL |
INDEPENDENT ASSURANCE& VERIFICATION S&T |
REMARKS
|
||||||||||||||||
SAMPLE BY |
FREQ. |
SAMPLE SIZE |
TEST BY |
REPORT |
S&T TYPE |
SAMPLE BY |
FREQ. |
SAMPLE SIZE |
TEST BY |
REPORT |
|
||||||||||
SOURCE INSPECTION |
|||||||||||||||||||||
Special Backfill, Crushed Stone (4132.02), Gravel (4132.03) |
|
AS 209
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
Crushed Concrete |
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
Granular Backfill |
Quality |
AS 209
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
Engr. Fabric (4196) |
Quality |
AS 496.01 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
Contractor Furnished Borrow |
|
CONTR |
CONTR |
IM 545 & Cert |
V |
RCE/ CONTR |
1/10 QC tests |
35 lb.
|
CTRL |
Test Report |
Note 4 |
||||||||||
GRADE INSPECTION |
|||||||||||||||||||||
Moisture Control, (QC by Contractor) Note 1 |
Proctor
|
CONTR |
1/ soil class |
25 lb |
CONTR |
Field Book & Test Report |
V (7)
IA (4) |
CONTR/RCE CONTR/DME |
1/ 10 req’d QC tests (min. 1)(5) 1/proj. |
25 lb.
25 lb. |
RCE/ DME CTRL |
Field Book
Test Report |
Note 8 |
||||||||
Moisture
|
CONTR |
1/lift/1500 ft (for max of 1300 cy) (6) |
3 lb |
CONTR |
Field Book & Test Report |
V (7)
IA (4) |
RCE (2)
DME |
1/ 10 req’d QC tests (min. 1)(5) Witness 1/proj. |
3 lb. |
RCE |
Field Book |
Note 8 |
|||||||||
Moisture & Density Control, including Special Compaction of Subgrade (2109.03C), (QC by Contractor) Note 1 |
Proctor
|
CONTR |
1/ soil class |
25 lb |
CONTR |
Field Book & Test Report |
V (7)
IA (4) |
CONTR/RCE CONTR/DME |
1/ 10 req’d QC tests (min. 1)(5) 1/proj. |
25 lb.
25 lb. |
RCE/ DME CTRL |
Field Book
Test Report |
Note 8 |
||||||||
Moisture
|
CONTR |
1/lift/1500 ft.(for max of 1300 cy) (6) |
3 lb |
CONTR |
Field Book & Test Report |
V (7)
IA (4) |
RCE (2)
DME |
1/ 10 req’d QC tests (min. 1)(5) Witness 1/proj. |
3 lb. |
RCE |
Field Book |
Note 8 |
|||||||||
In-place Density |
CONTR |
1/lift/1500 ft (for max of 1300 cy) (6) |
As req’d by test |
CONTR |
Field Book & Test Report |
V (7)
IA (4) |
RCE/ DME DME |
1/10 req’d QC tests (min. 1)(5) Witness 1/proj. |
|
RCE/ DME |
Field Book |
Note 8 |
|||||||||
Note 1: When Contractor QC testing is not required in the contact documents. The RCE will perform verification testing at the frequency listed for QC. Note 2: RCE will direct the Contractor to take a moisture sample beside the RCE verification sample location. Note 4: For earthwork quantities of less than 50,000 Yd3, no IA will be required. Note 5: If no QC tests are required, then no verification or independent assurance tests are required. Note 6: If source of excavation and moisture have been consistent and within moisture control limits and density has been greater than or equal to minimum density (if required), testing of each lift will be waived. Minimum frequency will be 1 per 1300 Yd3. Note 7: For earthwork quantities of less than 1300 Yd3, no verification tests will be required. Note 8: For Local agency projects not receiving Federal funding, Independent Assurance, IA, tests are not required. |
|||||||||||||||||||||
Sampling & Testing Guide-Minimum Frequency |
|||||||||||||||||||||
October 15, 2019 |
ROADWAY & BORROW EXCAVATION & EMBANKMENTS |
Matls. IM 204 |
|||||||||||||||||||
Supersedes April 16, 2019 |
Sections 2102, 2107, 2109 & 2432 |
Appendix A (US) Units |
|||||||||||||||||||
MATERIAL OR CONSTRUCTION ITEM |
TESTS |
METHOD OF ACCEPTANCE & RELATED IMs |
QUALITY CONTROL |
INDEPENDENT ASSURANCE& VERIFICATION S&T |
REMARKS
|
||||||||||||||||
SAMPLE BY |
FREQ. |
SAMPLE SIZE |
TEST BY |
REPORT |
S&T TYPE |
SAMPLE BY |
FREQ. |
SAMPLE SIZE |
TEST BY |
REPORT |
|
||||||||||
GRADE INSPECTION |
|||||||||||||||||||||
Moisture & Density Control of MSE wall backfill |
Proctor |
CONTR |
1/ source |
25 lb |
CONTR |
Field Book & Test Report |
|
|
|
|
|
|
|
||||||||
Moisture |
CONTR |
1/lift (for max of 250 cy) (1) |
3 lb |
CONTR |
Field Book & Test Report |
V
IA (2) |
RCE
DME |
Witness 1/ 10 req’d QC tests
1/proj. |
|
DME |
|
Note 3 |
|||||||||
In-place Density |
CONTR |
1/lift (for max of 250 cy) (1) |
As req’d by test |
CONTR |
Field Book & Test Report |
V
IA (2) |
RCE
DME |
Witness 1/10 req’d QC tests
1/proj. |
|
DME |
|
Note 3 |
|||||||||
Note 1: If source of excavation and moisture have been consistent and within moisture control limits and density has been greater than or equal to minimum density (if required), testing of each lift will be waived. Minimum frequency will be 1 per 250 Yd3. Note 2: For MSE wall backfill quantities of less than 50,000 Yd3, no IA will be required. Note 3: For Local agency projects not receiving Federal funding, Independent Assurance, IA, tests are not required |
|||||||||||||||||||||