Sampling & Testing Guide-Minimum FrequencyBASE REPAIR (2212), PAVEMENT REPAIR (PATCHES) |
|||||||||||||||||||
April 21, 2020 |
Matls. IM 204 |
||||||||||||||||||
Supersedes October 17, 2017 |
|
Appendix T |
|||||||||||||||||
MATERIAL OR CONSTRUCTION ITEM |
TESTS |
METHOD OF ACCEPTANCE & RELATED IMs |
QUALITY CONTROL |
INDEPENDENT ASSURANCE& VERIFICATION S&T |
REMARKS |
||||||||||||||
SAMPLE BY |
FREQ. |
SAMPLE SIZE |
TEST BY |
REPORT |
S&T TYPE |
SAMPLE BY |
FREQ. |
SAMPLE SIZE |
TEST BY |
REPORT |
|
||||||||
SOURCE INSPECTION |
|||||||||||||||||||
Aggregates Fine (4110) |
|
AS 209 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Aggregates Coarse (4115) |
|
AS 209 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Portland Cement (4101) |
Quality |
AS 401 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Fly Ash (4108) |
Quality |
AS 491.17 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
GGBFS (Ground Granulated Blast Furnace Slag) |
Quality |
AS 491.14 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Curing Compound (4105) |
Lab Tested |
|
|
|
|
|
|
|
|
|
|
|
|
||||||
Air Entraining Admixture (4103) |
Quality
|
AB 403
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Granular Backfill |
Gradation Quality |
AS Cert AS Cert |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Drain Tubing |
Quality |
AS 443 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Epoxy Grout |
|
AB 491.11 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Joint Seal (4136.02) |
Lab Tested |
AB 436.02 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Backer Rod (4136.02) |
|
AB 436.04 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Steel Reinforcing |
Quality |
AS 451 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Sampling & Testing Guide-Minimum FrequencyBASE REPAIR (2212), PAVEMENT REPAIR (PATCHES) |
|||||||||||||||||||||
April 21, 2020 |
Matls. IM 204 |
||||||||||||||||||||
Supersedes October 17, 2017 |
|
Appendix T |
|||||||||||||||||||
MATERIAL OR CONSTRUCTION ITEM |
TESTS |
METHOD OF ACCEPTANCE & RELATED IMs |
QUALITY CONTROL |
INDEPENDENT ASSURANCE& VERIFICATION S&T |
REMARKS
|
||||||||||||||||
SAMPLE BY |
FREQ. |
SAMPLE SIZE |
TEST BY |
REPORT |
S&T TYPE |
SAMPLE BY |
FREQ. |
SAMPLE SIZE |
TEST BY |
REPORT |
|
||||||||||
PLANT INSPECTION |
|||||||||||||||||||||
Aggregates-Coarse (4115) |
Grad |
CONTR |
CONTR |
|
V |
RCE/ CONTR |
RCE |
|
|
||||||||||||
|
Moist |
CONTR |
1000 gm |
CONTR |
|
|
|
|
|
|
|
|
|||||||||
|
Sp. Gr. |
CONTR |
1000 gm |
CONTR |
|
|
|
|
|
|
|
|
|||||||||
|
Quality |
AS 209 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
Aggregate- Fine (4110) |
Gradation |
CONTR |
CONTR |
830211 |
V |
RCE/ CONTR |
RCE |
|
|
||||||||||||
|
Moisture |
CONTR |
CONTR |
830211 |
|
|
|
|
|
|
See IM 528 if Moisture Probe is used |
||||||||||
|
Sp. Gr. |
CONTR |
CONTR |
830211 |
|
|
|
|
|
|
|
||||||||||
|
Quality |
AS 209 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
Portland Cement (4101) |
Quality |
AS Cert |
|
Each Load |
|
|
|
|
|
|
|
|
|
|
|||||||
Fly Ash |
Quality |
AS Cert |
|
Each Load |
|
|
|
|
|
|
|
|
|
|
|||||||
Air Entraining Admixture |
|
AB 403 |
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
Water Reducing Admixture |
|
AB 403 |
|
|
|
|
|
|
|
|
|
|
|
||||||||
Retarding Admixture |
|
AB 403 |
|
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
Sampling & Testing Guide-Minimum FrequencyBASE REPAIR (2212), PAVEMENT REPAIR (PATCHES) |
||||||||||||||||||||
April 21, 2020 |
Matls. IM 204 |
|||||||||||||||||||
Supersedes October 17, 2017 |
|
Appendix T |
||||||||||||||||||
MATERIAL OR CONSTRUCTION ITEM |
TESTS |
METHOD OF ACCEPTANCE & RELATED IMs |
QUALITY CONTROL |
INDEPENDENT ASSURANCE,& VERIFICATION S&T |
REMARKS
|
|||||||||||||||
SAMPLE BY |
FREQ. |
SAMPLE SIZE |
TEST BY |
REPORT |
S&T TYPE |
SAMPLE BY |
FREQ. |
SAMPLE SIZE |
TEST BY |
REPORT |
|
|||||||||
GRADE INSPECTION |
||||||||||||||||||||
Uncompacted HMA Mixture |
|
Scale ticket with JMF number |
|
|
|
|
|
|
|
|
|
|
|
Job Mix Formula (JMF) approved by DME |
||||||
Plastic Concrete |
Air Slump |
|
|
|
|
|
V V |
RCE RCE |
1/30 cy 1/30 cy
|
|
RCE RCE |
|
Minimum 1 per pour |
|||||||
Reinforcing Steel Epoxy-Coated Steel |
Quality Quality |
AS 451 AS 451 |
|
Each Shipment |
|
|
|
|
|
|
|
|
|
|
||||||
Calcium Chloride |
Concentr. |
RCE |
1/lot |
|
RCE |
|
|
|
|
|
|
|
|
|||||||
Smoothness for Compacted HMA or Hardened Conc. (2529.03) |
|
CONTR |
|
|
CONTR |
|
|
|
|
|
|
|
Approval by RCE See Plans/Specs for exclusions |
|||||||