TABLE D

 

Price Adjustment Schedules for Bridge Floor

Resurfacing & Overlay Projects

 

Density

Percent Payment

 

 

97.5% and Over

100%

97.4% - 97.0%

50%

96.9% and Below

Remove and replace

 

 

Slump          Target ¾”

Percent Payment

0 – 1”

100%

1 ¼” – 1 ½”

50%

Over 1 ½”

Remove and replace

 

 

Air Content

 

Percent Air          Target 6.5%

Percent Payment

 

 

Less than 4.0%

Remove and replace

4.0% - 4.4%

0%

4.5% - 4.9%

50%

5.0% - 5.4%

75%

5.5% - 7.5%

100%

7.6% - 8.0%

100%

8.1% - 8.5%

100%

8.6% - 9.0%

90%

9.1% - 9.5%

80%

9.6% - 10.0%

70%

10.1% and Over

Evaluate strength impact

 

Determining Deficient Area

 

An overlay density test will be representative of the width placed and:

 

·        For a distance extending one-half the distance to the next density test location measured along center line, or

 

·        To the end section if project is starting or ending.

 