Recommended Minimum Laydown Temperature (0C) |
||||||
|
Compacted Lift Thickness |
|||||
Base Temp (°C) |
13 mm |
19 mm |
25 mm |
40 mm |
50 mm |
75 mm + |
-7 to 0 |
-- |
-- |
-- |
-- |
-- |
141* |
+1 to +4 |
-- |
-- |
-- |
152 |
146 |
138 |
+5 to +10 |
-- |
-- |
154 |
149 |
141 |
135 |
+11 to +16 |
-- |
154 |
149 |
146 |
138 |
132 |
+17 to +21 |
154 |
149 |
143 |
141 |
135 |
129 |
+22 to +27 |
149 |
143 |
141 |
138 |
132 |
129 |
+28 to +32 |
143 |
138 |
135 |
132 |
129 |
127 |
Higher than +32 |
138 |
135 |
132 |
129 |
127 |
124 |
Rolling Time (min.) |
4 |
6 |
8 |
12 |
15 |
15+ |
*Place only on bases made of treated materials, not on frozen soils or untreated aggregates. |
Recommended Minimum Laydown Temperature (0F) |
||||||
|
Compacted Lift Thickness |
|||||
Base Temp (°F) |
½” |
¾” |
1” |
1 ½” |
2” |
3” + |
20 to 32 |
-- |
-- |
-- |
-- |
-- |
285* |
33 to 40 |
-- |
-- |
-- |
305 |
295 |
280 |
41 to 50 |
-- |
-- |
310 |
300 |
285 |
275 |
51 to 60 |
-- |
310 |
300 |
295 |
280 |
270 |
61 to 70 |
310 |
300 |
290 |
285 |
275 |
265 |
71 to 80 |
300 |
290 |
285 |
280 |
270 |
265 |
81 to 90 |
290 |
280 |
275 |
270 |
265 |
260 |
Higher than 90 |
280 |
275 |
270 |
265 |
260 |
255 |
Rolling Time (min.) |
4 |
6 |
8 |
12 |
15 |
15+ |
*Place only on bases made of treated materials, not on frozen soils or untreated aggregates. |