Bridges and Structures

CULVERT STANDARDS - MICROSTATION V8


yellow highlight = new

Model Name Revision Date File Description MicroStation DGN File PDF File
Culvert Extensions and Other Details
1043s1 02/17 Culvert Extension Quantities
exe icon
PDF Icon
1043s2 03/19 Culvert Extension Quantities
1044 05/14 Culvert Extension Details
1047 03/15 Culvert Extension Details
1060 04/12 Culvert Baffles
1061 04/12 Culvert Wiers
1070 04/16 Flume Chute Details
1071 03/19 Flume Chute Details
1072-1079 04/16 Flume Chute Details
1092 02/17 Revetment Protection
Flumes
RCF-01-12 05/13 Reinforced Concrete Flumes
exe icon
PDF Icon
RCF-02-12 04/12 Reinforced Concrete Flumes
FBJ-01-12 04/12 3 x 3 to 5 x 6 Flume Bell Joint Details
FBJ-02-12 04/12 6 x 3 to 6 x 8 Flume Bell Joint Details
FBJ-03-12 04/12 8 x 4 to 8 x 10 Flume Bell Joint Details
FBJ-04-12 04/12 10 x 5 to 10 x 12 Flume Bell Joint Details
FBJ-05-12 04/12 12 x 4 to 12 x 12 Flume Bell Joint Details
RCFB-01-12 04/12 3 x 3 to 5 x 6 Flume Basin Details
RCFB-02-12 04/12 6 x 3 to 6 x 8 Flume Basin Details
RCFB-03-12 04/12 8 x 4 to 8 x 10 Flume Basin Details
RCFB-04-12,
RCFB-05-12
04/12 10 x 5 to 10 x 12 Flume Basin Details
RCFB-06-12,
RCFB-07-12
04/12 12 x 4 to 12 x 12 Flume Basin Details
UPDATE NOTICE:
    The newly released Cast-In-Place Culverts - Single Span RCB, Twin RCB and Triple RCB dated July 2020 are designed and supplied with the new Parallel Wing Headwalls. The intent of the Bureau is to use Parallel Wing Headwalls when feasible in order to provide relative parity between the CIP and Precast Culvert options. The use of these newly released CIP Culverts and Parallel Wing Headwall Standards should follow the guidelines below: 
  • For all new RCB Culvert projects and those just entering final design, if the TSL shows flared wing headwalls then the Final Designer should contact the Preliminary Designer and verify whether the Flared Wing Headwalls are mandatory for the specific project or if they can be changed to the new Parallel Wing Headwalls, as there could possibly be a scenario where the change may not be desirable. If it can be changed to Parallel Wing Headwalls, it should be.
  • For RCB Culvert projects that are finished or have begun final design, no change is required when using the April 2012 standards. EXCEPTION: Any designs scheduled for the July 1, 2021 letting that are based on the April 2012 standards should be under consideration for re-design to the newly released July 2020 standards. 
  • The April 2012 Flared Wing Headwalls and CIP Culvert standards will still be available for Standards reference and e-Files on the Culvert Standards page of the Bridges & Structures Bureau website for the next year. 
  • Please note that the bureau also intends to release the new Precast Culvert Standards for use by all, and the Flared Wing Headwall Standards for county use and special project use in the near future. An email notification through GovDelivery will be sent out when those are available on the website. For more immediate needs, please contact Brett Kloss to request an unofficial copy.
Single Span RCB
RCB G1-20 07/20 Index of Sheets
exe icon
PDF Icon
RCB G2-20 07/20 General Notes & Specifications
RCB G3-20 07/20 Typical Culvert Barrel Details
RCB 3-3-20 07/20 Culvert Barrel Details,
3’-0 Barrel Sections
RCB 4-4-20 07/20 Culvert Barrel Details,
4’-0 Barrel Sections
RCB 5-3-20 -
RCB 5-6-20
07/20 Culvert Barrel Details,
5’-0 Barrel Sections
RCB 6-3-20 -
RCB 6-8-20
07/20 Culvert Barrel Details,
6’-0 Barrel Sections
RCB 8-4-20 -
RCB 8-10-20
07/20 Culvert Barrel Details,
8’-0 Barrel Sections
RCB 10-4-20 -
RCB 10-12-20
07/20 Culvert Barrel Details,
10’-0 Barrel Sections
RCB 12-4-20 -
RCB 12-12-20
07/20 Culvert Barrel Details,
12’-0 Barrel Sections
RCB 14-4-20 -
RCB 14-14-20
07/20 Culvert Barrel Details,
14’-0 Barrel Sections
RCB 16-4-20 -
RCB 16-14-20
07/20 Culvert Barrel Details,
16’-0 Barrel Sections
PWH 0-1-20 -
PWH 0-11-20
07/20 Parallel Wing Headwalls,
0° Skew
PWH 15-1-20 -
PWH 15-11-20
07/20 Parallel Wing Headwalls,
15° Skew
PWH 30-1-20 -
PWH 30-11-20
07/20 Parallel Wing Headwalls,
30° Skew
PWH 45-1-20 -
PWH 45-11-20
07/20 Parallel Wing Headwalls,
45° Skew
CBJ 1-20 07/20 Culvert Bell Joints,
3’, 4’ & 5’ Spans
CBJ 2-20 07/20 Culvert Bell Joints,
6’ & 8’ Spans
CBJ 3-20 07/20 Culvert Bell Joints,
10’ & 12’ Spans
CBJ 4-20 07/20 Culvert Bell Joints,
14’ & 16’ Spans
CBJ 5-20 07/20 Culvert Bell Joints,
All Spans
Twin RCB
TWRCB G1-20 07/20 Index of Sheets
exe icon
PDF Icon
TWRCB G2-20 07/20 General Notes & Specifications
TWRCB G3-20 07/20 Typical Culvert Barrel Details
TWRCB 8-4-20 -
TWRCB 8-10-20
07/20 Culvert Barrel Details,
8’-0 Barrel Sections
TWRCB 10-4-20 -
TWRCB 10-12-20
07/20 Culvert Barrel Details,
10’-0 Barrel Sections
TWRCB 12-4-20 -
TWRCB 12-12-20
07/20 Culvert Barrel Details,
12’-0 Barrel Sections
TWPWH 0-1-20 -
TWPWH 0-8-20
07/20 Parallel Wing Headwalls,
0° Skew
TWPWH 15-1-20 -
TWPWH 15-8-20
07/20 Parallel Wing Headwalls,
15° Skew
TWPWH 30-1-20 -
TWPWH 30-8-20
07/20 Parallel Wing Headwalls,
30° Skew
TWPWH 45-1-20 -
TWPWH 45-9-20
07/20 Parallel Wing Headwalls,
45° Skew
TWCBJ 1-20 07/20 Culvert Bell Joints,
8' Spans
TWCBJ 2-20 07/20 Culvert Bell Joints,
10' & 12' Spans
TWCBJ 3-20 07/20 Culvert Bell Joints,
All Spans
Triple RCB
TRRCB-G1-20 07/20 Index of Sheets
exe icon
PDF Icon
TRRCB-G2-20 07/20 General Notes & Specifications
TRRCB-G3-20 07/20 Typical Culvert Barrel Details
TRRCB 10-4-20 -
TRRCB 10-12-20
07/20 Culvert Barrel Details,
10’-0 Barrel Sections
TRRCB 12-4-20 -
TRRCB 12-12-20
07/20 Culvert Barrel Details,
12’-0 Barrel Sections
TRPWH 0-1-20 -
TRPWH 0-7-20
07/20 Parallel Wing Headwalls,
0° Skew
TRPWH 15-1-20 -
TRPWH 15-7-20
07/20 Parallel Wing Headwalls,
15° Skew
TRPWH 30-1-20 -
TRPWH 30-7-20
07/20 Parallel Wing Headwalls,
30° Skew
TRPWH 45-1-20 -
TRPWH 45-7-20
07/20 Parallel Wing Headwalls,
45° Skew
TRCBJ 1-20 07/20 Culvert Bell Joints,
10' Spans
TRCBJ 2-20 07/20 Culvert Bell Joints,
12' Spans
TRCBJ 3-20
07/20 Culvert Bell Joints, All Spans
April 2012 Culvert Standards - outdated
Single RCB Single Reinforced Concrete Box Culvert Standards
exe icon
PDF Icon
Twin RCB Twin Reinforced Concrete Box Culvert Standards
exe icon
PDF Icon
Triple RCB Triple Reinforced Concrete Box Culvert Standards
exe icon
PDF Icon